Class D Fire Extinguisher MFZ/D1-B [YT22693-B] (Combustible Metal Fire Suppression)
Voltronic
1,460 ₴

SKU ManualCallPoint (Red)
ManualCallPoint Jeweller is a wireless manual call point for emergency alarm activation. The device allows activating an alarm in an emergency situation. The button can be reset using a special tool (key) included in the kit. The device is intended for indoor installation only.
To transmit alarms and events, ManualCallPoint exchanges data with the hub via the secure Jeweller protocol. Communication range is up to 1700 meters in the absence of obstacles.
The ManualCallPoint button allows activating an alarm during an emergency. To do this, lift the transparent protective cover (if installed) and press the central part (the fragile, restorable element). The fragile element shifts inward and raises the alarm, while two yellow stripes appear above and below it, indicating the status of the device.
Under appropriate settings, the system activates the built-in sirens of fire detectors and intrusion sirens. Consequently, the alarm signal is sent to the central monitoring station (CMS), and users receive acoustic alarm notifications in Ajax. The system allows configuring critical notifications that arrive even if the sound is muted or the Do Not Disturb mode is activated.
The alarm will sound until the button is reset using the special tool included in the kit. To do this, insert the key into the corresponding hole.
After resetting, the button is ready for reuse.
The device features a transparent cover that protects against accidental presses during installation and use. However, installing the cover is optional.
ManualCallPoint operates in two modes: Fire Alarm Button and Scenario Activator.
Fire Alarm Button Mode
If ManualCallPoint is pressed in Fire Alarm Button mode, the system transmits an alarm signal to users in the app and to the CMS.
Scenario Activator Mode
In Scenario Activator mode, ManualCallPoint allows controlling one or more automation devices using the button.
Functional Elements:
Transparent protective cover.
LED indicator.
Fragile restorable element.
SmartBracket mounting panel.
Tamper button. Triggers if an intruder attempts to tear the button housing off the surface or remove it from the mount.
Power button.
QR code with device identifier to add the button to the hub.
Hole for a special tool.
Special tool (key).
Brand
Ajax
Ajax Product Lines
Baseline
Model
ManualCallPoint
Detector Type
Manual
Sensor Type
Wireless
Compatibility
Hub 2 Plus,
Hub 2 (4G),
Hub 2 (2G),
Hub Hybrid (2G),
Hub Hybrid (4G),
ReX,
ReX 2,
Hub Plus
Sabotage Protection
Anti-breakage tamper
Notifies of attempts to tear the button off the surface or remove it from the mounting panel.
Anti-spoofing Protection
Device authentication
Connection Loss Detection
From 36 s
Depends on Jeweller or Jeweller/Fibra settings.
Communication
Jeweller Communication Technology
Proprietary wireless technology for transmitting commands, alarms, and events. Features:
Two-way communication.
Advanced sabotage protection.
Block encryption with a floating key.
Instant notifications.
Remote configuration in Ajax apps.
Radio Frequency Ranges
866.0–866.5 MHz
Maximum Effective Radiated Power (ERP)
Up to 25 mW
Automatic power control to reduce energy consumption and interference.
Radio Signal Modulation
GFSK
Radio Communication Range
Up to 1,700 m
Between the button and the hub (or range extender) in the absence of obstacles.
Encrypted Communication
All stored and transmitted data is protected by block encryption with a floating key.
Radio Frequency Hopping
Prevents radio interference and radio signal interception.
Wireless Signal Range
1700 m
Additional Features
Restorable flexible element
Activates the button
When pressing the central part (flexible element), the button shifts inward and raises the alarm or triggers a scenario. Two yellow stripes appear above and below, indicating the device status.
Operating Modes
Fire alarm button
Scenario activator
During appropriate settings, raises an alarm or controls Ajax automation devices.
LED Status Indication
Fire alarm
Malfunctions
The LED indicator on the device housing lights up if a fire alarm triggers or malfunctions occur.
Synchronous Fire Detector Alarm
Upon button press
If the flexible element is pressed, the fire detectors in the system turn on their built-in sirens.
Critical Alerts
The system can turn on intrusion sirens and send acoustic alarm notifications to users, even if the sound is turned off, Do Not Disturb mode is activated, or headphones are connected.
Protection Against Accidental Presses
Lift the transparent cover to access the flexible element. The cover protects against false button presses.
Alarm Transmission to CMS
Can be disabled only for the Blue version
Operating Temperature Range
0 °S - +50 °S
Operating Humidity
No more than 80%
Power Supply
2 x CR123A
Dimensions
102×104×39 mm
Weight
214 g