Motion Sensor (100W, 220V)
Voltronic
231 ₴

SKU FireProtect 2 RB (Heat/CO (35310)
FireProtect 2 (Heat/CO) Jeweller is a wireless fire detector with a built-in siren. Designed for indoor installation. Detects rapid temperature rise and dangerous levels of CO (carbon monoxide) concentration. The detector can operate autonomously without a hub.
Available in two modifications: with sealed batteries (SB in the name) operating for 10 years, and with replaceable batteries (RB in the name) operating up to 7 years.
The detector operates as part of the Ajax security system, communicating with the hub via the proprietary Jeweller encrypted radio protocol. Communication range with the hub without obstacles is up to 1,700 meters.
The detector is equipped with a piezo buzzer siren for audible alarm and event notifications with a volume of up to 85 dB (at a distance of 3 meters). The detector is always active, responding to fire hazards 24/7 regardless of the system arming mode.
A high-temperature alarm is easily distinguishable from a high-CO alarm thanks to differentiated audible and LED indicators. For more details on alert types, consult the indication description section.
FireProtect 2 is protected by a tamper switch. It monitors removal from the SmartBracket mounting plate: the detector triggers LED indication and sends notifications to Ajax app users and the central monitoring station (CMS).
Ajax automation devices can respond to FireProtect 2 alarms and trigger user-defined automation scenarios. For example, a WallSwitch relay can shut down the ventilation system and turn on emergency lighting upon alarm.
Heat Sensor
Rapid temperature rise and threshold excess are detected by two built-in Class A1 thermistors. Class A1 thermistors trigger an alarm upon detecting a rapid temperature rise or static temperature within +54°C to +65°C.
FireProtect 2 reports a threshold excess once the temperature exceeds +64°C. The detector notifies of a rapid spike if the temperature increases by 10°C within one minute. If the temperature jumps by 20°C or more, the detector alerts immediately.
CO (Carbon Monoxide) Sensor
Dangerous carbon monoxide concentration is detected by a chemical sensor integrated into FireProtect 2. Its operation principle is based on detecting CO through a chemical reaction inside an electrolyte cell. When a specific CO concentration threshold is reached, the chemical reaction triggers an alarm signal.
The detector initiates an alarm if the CO concentration reaches:
50 ppm (0.005%) and above – within 90 minutes max.
100 ppm (0.01%) and above – within 40 minutes max.
300 ppm (0.03%) and above – within 3 minutes max.
A CO concentration of 400 ppm (0.04%) for three hours poses a life-threatening danger. The detector ceases alarming once the concentration drops to 40 ppm (0.004%).
Test/Mute Button
To activate the Test/Mute button, lightly press the center of the front panel by hand or using a suitable tool (e.g. a mop handle) if mounted out of reach. Test/Mute is a mechanical button located under the front faceplate.
The button serves several functions:
In normal standby mode – runs a detector self-test.
During an alarm – mutes the detector siren or interconnected fire alarm across all system detectors for 10 minutes.
In case of fault, low battery, or end-of-life – silences the acoustic and LED notification for 12 hours.
Interconnected Fire Detector Alarm
All FireProtect 2 detectors support interconnected alarms. This feature activates the integrated sirens of all system fire detectors as soon as at least one detects an alarm. FireProtect 2 sirens activate within 20 seconds of alarm detection. FireProtect and FireProtect Plus activate within the Jeweller (or Jeweller/Fibra) hub-detector polling interval, but no later than 60 seconds.
FireProtect 2 detectors feature differentiated audible and visual alerts per alarm type for quick identification. In an interconnected alarm, FireProtect 2 units reproduce the exact alarm type triggered by the initiating detector. The initiating detector is additionally indicated by LED. FireProtect and FireProtect Plus signal all alarm types with an identical tone.
The Ajax security system can transmit alarms and events to PRO Desktop monitoring software and central monitoring stations (CMS) via SurGard (Contact ID), SIA DC-09 (ADM-CID), ADEMCO 685, and other protocols.
Addressability allows transmitting not just event codes, but device type, assigned name, virtual room, and security group to PRO Desktop and CMS. Transmitted parameters may vary depending on CMS type and selected communication protocol.
Brand
Ajax
Model
FireProtect 2 RB (Heat/CO)
Detector Type
combined detector
Sensor Type
wireless
Sensing Elements
Temperature sensor
CO (carbon monoxide) sensor
Compatibility
Hub Plus,
Hub 2 (2G),
Hub 2 (4G),
Hub 2 Plus,
Hub Hybrid (2G),
Hub Hybrid (4G),
ReX,
ReX 2
Detected Gas
CO
High Temperature Detection
Sensing element complies with Class A1 heat detector requirements under EN 54-5 and BS 5446-2. Threshold alarm at temperatures above +64°C. Rate-of-rise alarm when temperature increases by more than 10°C in 1 minute (or faster)
Tamper Protection
Anti-tamper switch against opening and detachment. Alerts on attempts to detach detector from mounting surface or SmartBracket panel.
Spoofing prevention device authentication. Communication loss detection within 15 minutes. Ping loss detection time depends on unacknowledged packet count settings (configured in Jeweller or Jeweller/Fibra settings). Fixed polling interval – 300 seconds.
Carbon Monoxide (CO) Detection
Sensing element: chemical CO sensor. Alarm on cumulative CO threshold:
over 50 ppm (0.005%) – max 90 minutes
over 100 ppm (0.01%) – max 40 minutes
over 300 ppm (0.03%) – max 3 minutes. Dangerous life-threatening concentration: 400 ppm (0.04%) for 3 hours. Alarm ceases when CO concentration drops below 50 ppm (0.005%) within 1 minute. Sensor service life: 10 years (replacement required after 10 years).
Communication
Jeweller wireless communication technology. Proprietary two-way radio protocol for alarms and events. Features: - Two-way communication.
- Device spoofing prevention.
- Block encryption with floating key.
- Instant notifications.
- Remote configuration via Ajax apps.
Frequency bands: 868.0 – 868.6 MHz
Maximum Effective Radiated Power (ERP): up to 20 mW. Automatic power control to reduce power consumption and radio interference. GFSK modulation. Radio communication range: up to 1700 m line-of-sight between detector and hub (or range extender). Data encryption: all stored and transmitted data is protected by block cipher with floating key. Frequency hopping for interference and jamming resistance.
FACP Connection Method
wireless
Wireless Range
1700 m
Additional Features
Built-in siren: 85 dB volume at 3 meters. Audible alarm alert. Operates until trigger source cleared or silenced by user. Interconnected fire alarm: activates all fire detectors in the system when one is triggered, within one hub-detector polling cycle (up to 20 seconds). LED indication: green — power status (flashes every 56 seconds, compliant with EN 50291); yellow — malfunction indicator (low battery, contaminated chamber, end of life); red — fire alarm indicator. Front-panel mechanical button: triggers chamber test in normal mode, silences alarm or fault alerts.
Ingress Protection
IP20
Operating Temperature Range
0 °C to +50 °C
Operating Humidity
up to 80% non-condensing
Power Supply
2 x CR123A
Dimensions
44×86×86 mm
Weight
149 g