DLM — Electronics, Tools & Home Store

Categories

Categories currently unavailable.

Open catalog
Language
UAEN

Sale AGM Battery LPM 6V - 1.3 Ah

SKU 38653

Description

AGM Lead-Acid Battery

External universal SLA battery manufactured using AGM technology—a completely sealed external power source that requires no maintenance during storage and operation.

The manufacturing technology of AGM universal external batteries (absorbent glass mat) features an absorbent fiberglass pad inside the battery. Batteries of this type handle increased loads exceptionally well.

Advantages of AGM Battery:

  • Charge/discharge cycle life of an AGM battery is 400* (approximately 5 years, depending on operating conditions).
  • The battery can be installed in residential premises. The absence of free liquid electrolyte between plates and complete housing sealing eliminate acid leaks and guarantee zero harmful emissions.
  • In practical use, these AGM lead-acid batteries demonstrate stable results when operating under low (-20°C) and high (+50°C) ambient temperatures.
  • During operation, the AGM lead-acid battery is capable of withstanding prolonged discharge, cyclic discharge, deep discharge, and high-current discharge.
  • Batteries of this type feature low self-discharge rates during long-term storage and reliable self-protection against overdischarge and battery overcharging.

Production Features of AGM Batteries

Inside the battery manufactured using AGM technology, porous insulating pads made of fine fiberglass are placed. The separators and electrode plates are tightly pressed against each other. Thus, no free liquid electrolyte remains between the battery plates, as it is contained within the separator and the active part of the electrodes.

The amount of liquid electrolyte is metered so that small pores are filled with acid while large pores ensure gas circulation.

The SLA construction features an improved gas recombination system—oxygen and hydrogen generated as a result of chemical processes do not have time to evaporate outside the sealed housing before condensation occurs.

Applications: Why is an AGM Lead-Acid Battery Needed?

The universal external rechargeable battery is used:

  • In telecommunications and other communication systems, including as an external SLA for charging mobile phones, walkie-talkies, etc.
  • For equipping video surveillance, security, fire, and other alarm systems.
  • In uninterruptible power supply systems for server stations.
  • As a power source for medical, laboratory, commercial, and other specialized equipment.
  • In energy storage systems from alternative sources (batteries for solar panels).
  • As a battery for emergency or LED luminaires.
  • As batteries for uninterruptible power supply units and UPSs.

Which SLAs are Suitable for Emergency Lighting Systems in Ukraine, and Which SLA Should You Buy for a UPS?

Battery selection depends on the power rating of consumers to be connected, as well as the required backup runtime of electrical equipment from the SLA.

The external AGM battery for UPS must have a sufficient capacity margin, a wide operating temperature range, and a long service life.

Before deciding which battery is best to buy for a UPS, carefully study the parameters of the uninterruptible power source and determine the amount of runtime required for the electrical equipment.

AGM batteries are in high demand among consumers who want to buy an affordable and universal SLA for a heating boiler, emergency lighting systems, or autonomous water supply.

Before choosing a battery for solar panels, uninterruptible power sources, or other purposes, consult a specialist.

How to Avoid Battery Capacity Loss During Frequent Power Outages?

Two important care rules for AGM, GEL, and MG batteries:

  1. Do not frequently discharge the SLA by more than 30% of its capacity (keep this in mind when calculating battery capacity).
  2. After discharge, the battery must be fully charged with a current of 1/10 of its capacity for 10 hours.

IMPORTANT! If a group of several batteries connected in parallel or series is used, then:

  • all batteries must have identical capacity,
  • be of the same type (AGM, GEL, or MG),
  • have the same voltage, the same number of charge/discharge cycles,
  • be from the same batch of the same trademark.

Violation of these requirements causes premature failure of one or more SLAs and is not covered by warranty. You can obtain more detailed information from our article.

On the official LogicPower website, you can order UPS battery packs and other types of batteries with delivery across Ukraine. Price is directly from the manufacturer.

Warranty is 12 months.

The company ensures 100% fulfillment of warranty obligations. Maintenance and repair of LogicPower equipment is carried out in certified service centers.

*Depending on operating conditions

Specifications

Technical Specifications

Nominal voltage, V
6
Nominal capacity, Ah
1,3
Type
AGM lead-acid
Terminal type
T1
Cycle count
400
Enclosure material
plastic
Nominal charging current, A
0,13
Charging voltage (buffer mode), V
6,75-6,9
Charging voltage (cyclic mode), V
7,35-7,5
Short-circuit current, A
58.5
Internal resistance, mOm
50
Length, mm
97
Width, mm
24
Height, mm
51
Warranty, months
6
Height with terminals, mm
55
Battery storage temperature, °C
-25 ~ +50
Operating charging temperature, °C
-20 ~ +50
Operating discharging temperature, °C
-20 ~ +50
Weight, kg
0.295

General Information

Model
Sale AGM Battery LPM 6V - 1.3 Ah
SKU
38653
Condition
New (Original factory package)
Warranty
Official manufacturer warranty

Delivery & Payment

Nova Poshta delivery across Ukraine

Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.

Payment & Pick-up

Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.

Shopping Cart

0 items

Your cart is empty

Add items from the catalog to place an order.

Explore Catalog