DLM — Electronics, Tools & Home Store

Categories

Categories currently unavailable.

Open catalog
Language
UAEN
Pure Sine Wave UPS 48V LPY-B-PSW-6000VA+(4200W)10A/20A1 / 5

Pure Sine Wave UPS 48V LPY-B-PSW-6000VA+(4200W)10A/20A

SKU 6615

Description

Pure Sine Wave UPS 48V LPY-B-PSW-6000VA+(4200W)10A/20A

Uninterruptible Power Supplies (UPS) with pure sine wave ensure autonomous operation of electrical equipment from a battery in case of power outages from the general grid.

Features a pass-through neutral, designed for use with phase-dependent equipment.

Ensuring stable and uninterrupted power for your appliances

When using a pure sine wave UPS and an external battery, the equipment operates under optimal conditions both during power outages and when running on utility power. Mode switching occurs automatically. Equipment connected to the UPS does not shut down, as the switching speed takes fractions of a second.

UPS + battery

Uninterruptible power supply for computers, TVs...

Protect expensive equipment from sudden power surges in the grid

The 48V LPY-B-PSW-6000VA+(4200W)10A/20A uninterruptible power supply has a built-in voltage stabilization function ranging from 140-275 V input to 220±10% output. This is especially important for sensitive devices (computers, TVs, laboratory equipment, servers, network devices, etc.).

Where are 48V LPY-B-PSW-6000VA+(4200W)10A/20A pure sine wave uninterruptible power supplies with an external battery used?

Audio and video equipment:

  • To reduce grid interference and noise. This improves the quality of audio and video recordings and increases the efficiency of studio equipment.
  • To support the uninterrupted operation of professional equipment such as mixers, amplifiers, and speakers.

Industrial equipment:

  • To ensure continuity of production processes by installing uninterruptible power supplies for controllers, automated systems, and other critical electrical equipment.
  • To maintain stable operation of production equipment without short circuits, overheating, and wear of safety units.

Home appliances:

Uninterruptible power supply for computers, TVs, refrigerators, air conditioners, security systems..

  • To provide uninterrupted power for computers, TVs, refrigerators, air conditioners, security systems, and other household appliances during power outages.

Pure sine wave UPS and external batteries are used:

  • as uninterruptible power supplies for gas or solid-fuel heating boilers;
  • UPS for emergency lighting;
  • to provide backup power for server stations and telecommunication equipment;
  • pure sine wave UPS for circulation pumps.

The UPS must be used only in conjunction with a rechargeable battery (battery not included), which must match the technical specifications of the device.

Types of external rechargeable batteries that can be connected to the UPS:

Types of external rechargeable batteries that can be connected to the UPS

Connection diagrams for the 48V LPY-B-PSW-6000VA+(4200W)10A/20A pure sine wave UPS

Connecting via an electrical distribution board will allow you not only to use electrical appliances in usual locations, but also to control the connection via circuit breakers. Attention! Work on connecting the UPS through the electrical panel must be performed by a qualified electrician with the appropriate safety rating.

UPS connection diagrams with correct sine wave

Attention! The UPS will turn on automatically! It is forbidden to press the power button and interrupt self-diagnostics!

Selection of a UPS for heating boilers and emergency lighting systems

Before buying a pure (correct) sine wave UPS, you need to consider the following technical specifications:

  • Total power consumption of electrical appliances that will be connected to the UPS. The parameter can be found in the technical documentation of each piece of equipment.

  • Inrush power - the amount of electricity consumed by the device when turned on. To connect a UPS to equipment with high inrush currents, you must choose a more powerful uninterruptible power supply model.

  • The backup runtime required for the pump from the battery. Determined by the individual needs of the consumer. For long-term autonomy, you should choose an output pure sine wave UPS to which an external battery can be connected.

To ensure your uninterruptible power supply with an external battery works long and efficiently, follow the manufacturer's recommendations and instructions given in the operation manual. This will help avoid errors during device care and maintenance.

Specifications

Technical Specifications

Type
line-interactive with pure sine wave
Series
LPY
Capacity, VA/W
6000/4200
Nominal battery voltage, V
48
Grid charging current, A
10/20
Number of outputs
2
Installation
floor-standing
Number of phases
1
Output voltage waveform
pure sine wave
Input voltage range, V
140-275
Output voltage, V
220±10%
Frequency range, Hz
50/60
Switching time, ms
4-6
Grid connection type
terminals
Load connection type to UPS
Schuko socket
Battery connection type to UPS
terminals
AVR voltage stabilization function
yes
Protection
against short circuit, voltage surges, overload, discharge, overcharge of batteries
Indication type
LCD
Operating temperature, °C
0 ~ +40
Enclosure material
metal
Warranty, months
24
Color
black
Length, mm
400
Width, mm
220
Height, mm
290
Weight, kg
22.3

General Information

Model
Pure Sine Wave UPS 48V LPY-B-PSW-6000VA+(4200W)10A/20A
SKU
6615
Condition
New (Original factory package)
Warranty
Official manufacturer warranty

Delivery & Payment

Nova Poshta delivery across Ukraine

Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.

Payment & Pick-up

Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.

Shopping Cart

0 items

Your cart is empty

Add items from the catalog to place an order.

Explore Catalog