ATMOS AC 25 S Solid Fuel Boiler (with Burner Flange)
ATMOS
119,784 ₴
1 / 3SKU 000002483
Structurally, the boiler is an assembly-welded construction consisting of a body (1) with a combustion chamber (firebox) (2). The convection section of the boiler consists of a three-pass heat exchanger (3).
The boiler body is manufactured in the form of a parallelepiped with double walls separated by water partitions. Thermal insulation (15) is fixed on the outer surface of the body beneath the decorative casing.
Fuel for the combustion process is loaded onto the grate (11) through the loading door (5). The grate is made of thick-walled pipes through which water from the boiler water jacket constantly circulates, making burnout impossible. Fuel combustion in the firebox occurs with the participation of air supplied through the air supply channel (19). The amount of air required for combustion is automatically regulated by the automatic control unit (16).
High-temperature combustion products, while passing through the heat exchanger, transfer heat via convection to the coolant (water) circulating through the boiler water jacket.
Supply and return of the coolant are carried out through the return mains water (8) and direct mains water (7) stub pipes, respectively.
Flue gases exit externally through the chimney (10) located at the rear of the boiler.
Ash generated during the fuel combustion process is dumped into the lower part of the boiler body, where the ash pan (12) is located. To clean the grate, a lifter (18) is used, operated via a lever (20) (absent in the 12 kW model).
The boiler firebox allows burning the amount of fuel necessary to maintain the temperature set by the user on the control unit panel. The controller continuously measures the boiler water temperature and, based on these data, controls the fan operation. Connection of the heating system circulation pump to the controller is provided.
A nozzle for draining water from the boiler (9) is located on the lower part of the rear wall of the body.
Inspection doors (6), located on the front wall of the boiler, are required for periodic cleaning of the grate and lifter, as well as for emptying the ash pan. Doors (4) are provided for periodic maintenance (cleaning) of the heat exchanger.
The boiler design (capacities of 12, 17, 20, 24, 33 kW) provides the possibility of installing a mechanical draft regulator (14).
The Marten Comfort Pellet boiler is equipped with a flare burner, auger, and hopper.
The delivery set includes:
Solid fuel boiler;
Pellet hopper;
Flare pellet burner;
Pellet feed auger;
Control unit;
Manual and poker.
Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.
Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.