MULTI-SPLIT SYSTEM ERGO

The ERGO multi-split system is an air conditioner with one outdoor unit and multiple indoor units connected in parallel. Such air conditioners optimize facade space on buildings while allowing individual microclimate control in all rooms.

The ERGO multi-split system is equipped with a reliable DC-inverter compressor featuring reduced noise levels and a wide compressor speed regulation range. For efficient system operation control, an original and reliable matching algorithm for compressor performance, fan motor, and electronic expansion valves is employed.

DC-INVERTER OUTDOOR UNIT FAN

A direct current (DC) motor is used for the outdoor unit fan, allowing operation at 5 different speeds depending on the system load, which specifically affects energy efficiency and noise levels.
Additionally, the DC motor performs reverse-mode cleaning of the outdoor unit heat exchanger to remove contaminants, helping to increase the air conditioner's service life.

REMOTE SMART CONTROL

SMART series air conditioners
are fully ready for smartphone control within Wi-Fi network coverage. Using the user-friendly NetHome Plus app, you can turn the air conditioner on and off, change operating modes, adjust the temperature, and manage scheduled on/off times using daily or weekly timers.

* A link to the app can be found on the ERGO website in the INSTRUCTIONS section of the corresponding air conditioner model

LOW-TEMPERATURE HEATING MODE

The air conditioner is capable of operating in heating mode at outdoor air temperatures down to -15°C.

RELIABLE WINTER HEATING

For stable and efficient operation at sub-zero temperatures, the outdoor unit is equipped with a winter kit:
- compressor crankcase heating element maintains oil viscosity levels.
- outdoor unit base pan heating element prevents potential ice accumulation.

FOLLOW ME FUNCTION

When this function is activated, the air conditioner temperature control unit receives current temperature data from the remote control's thermal sensor, allowing more precise adjustment of the air conditioner operation based on the temperature directly in the zone where the remote (users) is located. The signal range does not exceed 8 meters of direct line of sight between the remote and the indoor unit.

+8°C TEMPERATURE MAINTENANCE

The air conditioner control system can maintain a room temperature of +8°C to prevent walls from cooling down excessively and water pipes from freezing. This is relevant for country houses, garages, or when owners are away on vacation in the winter. In this case, the air conditioner consumes less electricity since the outdoor/indoor temperature differential is reduced.

DUAL AIR FILTRATION

The efficient high-density anti-dust filter is the first step: it cleans the air passing through it and, of course, through the indoor unit heat exchanger coils.
Step two: a titanium dioxide (TiO2) photocatalytic filter cleans the air of formaldehyde, ammonia, hydrogen sulfide, and other impurities. The filter restores its properties under direct sunlight and does not require constant replacement.

ENVIRONMENTALLY SAFE REFRIGERANT

R32 refrigerant is more eco-friendly: R32 has a 65% lower GWP (Global Warming Potential) than R410A; and it is more efficient: R32 has a 30% lower density than R410A, resulting in lower mass consumption at identical capacity outputs.

STANDARD FEATURES

REFRIGERANT LEAKAGE DETECTION
(IN COOLING MODE)

The temperature sensor mounted on the evaporator detects refrigerant «superheating» at the evaporator inlet, the processor displays the «EC» error code on the indoor unit display and shuts down the compressor to prevent damage.

SLEEP
MODE

The mode is activated by pressing the SLEEP button on the remote control. Activating the mode during cooling/heating operation increases/decreases the temperature by 1°C per hour for the first 2 hours, after which the air temperature stabilizes, and the mode automatically turns off 7 hours after activation.

SELF-DIAGNOSIS
FUNCTION

The air conditioner controller continuously monitors operating parameters; in case of deviations from normal values, the air conditioner stops and the fault code is displayed on the LED screen.

WARM
START

When using heating mode, the indoor unit fan turns on after a 3-minute delay required to heat up the heat exchanger, preventing cold air discharge into the room.

INDEPENDENT
DEHUMIDIFICATION

When dehumidification mode is enabled, effective air drying occurs without a noticeable change in the temperature of the conditioned space.

LOUVER ANGLE
MEMORY

Upon the next power-on of the air conditioner, the automatic air louvers return to the position they were in before being turned off. If continuous swing mode was set, it will also be activated.

24-HOUR
TIMER

It is possible to set automatic switching on or off of the air conditioner via the set timer within 24 hours, with a 0.5-hour interval.

AUTORESTART

After power is restored, the air conditioner automatically turns back on with the settings that were in effect prior to the power outage.

REMOTE CONTROL
BACKLIGHT

Allows comfortable use of the remote control even at night.

1W STANDBY
MODE

Only this much is consumed by the air conditioner when turned off.

LED
DISPLAY

A large display facilitates setup and control of the air conditioner. Provision is made to turn it off completely.

TURBO
MODE

High-power mode activates maximum air conditioner performance in the specified operating mode and allows reaching the required temperature faster.

SELF-CLEANING
FUNCTION

Designed to remove dust, mold, and grease that, remaining on the heat exchanger surface, can cause unpleasant odors. When the function is activated, first in low cooling mode and then in ventilation mode, dust is washed off the heat exchanger by condensate. The cleaned heat exchanger is then dried in low heating mode.



DESIGN FEATURES OF THE SERIES
MULTI-SPLIT SYSTEM

ENHANCED
HEAT TRANSFER

The units use heat exchangers with specially designed "Innergrove copper" tubes, which increases heat transfer by 28% and, consequently, increases system operating efficiency.



FIRE-RESISTANT
DESIGN

The electrical box housing the control board and terminal block is made of fire-retardant (5VA rating) ABS plastic, and the outer surface is covered with sheet metal.



DUAL
DRAINAGE

Dual drainage design: drainage can be connected on the left or right as needed.



GOLDEN FIN
COATING

Corrosion protection. A special anti-corrosion coating on the heat exchangers protects against weather phenomena and aggressive external environment impacts, improving heat exchange.






Specifications

Technical Specifications

Air conditioner type
Multi-split system
Indoor unit type
Wall-mounted
Trademark
ERGO
Model
ERGO ACI 1835 ODU MSH(2) + ACI 0935 IDU MSW WIFI x 2
Capacity (cooling/heating), BTU/h
18000 / 19000 (outdoor unit) 9000 / 10000 (indoor unit) x 2
Compressor control
INVERTER
Recommended room area (for cooling mode) sq.m
50
Cooling capacity, W
5300
Heating capacity, W
4800
Energy efficiency class (cooling)
A++
Energy efficiency class (heating)
A
Energy efficiency ratio SEER (cooling)
6.1
Coefficient of performance SCOP (heating)
3.8
Coefficient of performance COP (heating)
3,71
Annual electricity consumption (heating), kWh / year
1540
Sound power level, indoor unit, (max / med / min / silent), dB(A)
54
Sound power level, outdoor unit, (max), dB(A)
65
Sound pressure, indoor unit (max / med / min / silent), dB(A)
40/30/26/21
Sound pressure, outdoor unit, (max), dB(A)
54
Dehumidification, l/h
2 х 1.0
Airflow, indoor unit (max / med / min)
520 / 460 / 340
Indoor unit fan speed, cooling, rpm
1030 / 850 / 700
Indoor unit fan speed, heating, rpm
1030 / 850 / 700
Operating temperature range for indoor unit (cooling / heating), °C
+17…+32 / 0…+30
Operating temperature range of outdoor unit (cooling/heating), °C
-15…+50 / -15…+24
Supply voltage / frequency / number of phases
187-265 V / 50 Hz / 1 ph
Nominal power consumption during cooling, W
1635
Nominal power consumption during heating, W
1500
Rated current during cooling, A
7.3
Rated current during heating, A
6.6
Maximum power consumption (cooling/heating), W
3050
Maximum operating current (cooling/heating), A
13
Enclosure protection rating, indoor unit
IPX0
Enclosure protection rating, outdoor unit
IPX4
Internet control
Yes
TURBO cooling / heating mode
Yes
Ventilation / cooling mode
Yes
Heating mode
Yes
Dehumidification mode
Yes
Automatic mode
Yes
Night mode
Yes
Auto-restart function
Yes
Outdoor unit anti-icing protection function
Yes
Louver Angle Memory Function
Yes
Self-Diagnosis Function
Yes
Set Temperature Control Function via Remote Controller Temperature Sensor
FOLLOW ME
Low-Temperature Cooling Function, °C
down to -15
Self-Cleaning Function
Yes
Other Functions
warm start, +8°C temperature maintenance, low-temperature cooling mode down to -15°C, automatic outdoor unit cleaning
Washable Anti-Dust Filter
Yes
Hydrophilic heat exchanger fin coating
Golden Fin coating
On / Off Timer
24 hours
Remote Control
infrared remote control
Airflow Direction Control (Up / Down)
via remote control
Airflow Direction Control (Left / Right)
manual
Temperature Range Setting, °C
17 ... 30
Low ambient temperature operation, °C
down to -15
Operating mode display
hidden LED display
Other design features
Outdoor unit base pan and compressor crankcase heater, 2 x DC motors: compressor, outdoor fan, double drainage design
Indoor Unit (W x D x H), mm
805x194x285 (х2)
Indoor Unit in Packaging (W x D x H), mm
870x270x360 (х2)
Outdoor Unit (W x D x H), mm
805x330x554
Outdoor Unit in Packaging (W x D x H), mm
915x370x615
Indoor Unit NET Weight, kg
7.6 (х2)
Indoor Unit GROSS Weight, kg
9.7 (х2)
Outdoor Unit NET Weight, kg
35
Outdoor Unit GROSS Weight, kg
38
Package contents
Indoor unit x 2 Outdoor unit Remote control x 2 Batteries 2 x 2xAAA Wi-Fi connection module x 2 Catalytic filter x 2 Mounting kit (screws and wall plugs for indoor unit installation) x 2 Outdoor unit crankcase drain nozzle x 2 Warranty card User manual
Barcode
6900070758051 (indoor unit) / 690070758402 (outdoor unit)
Air Conditioner Power Supply Connection
Indoor unit side
Compressor Manufacturer Brand
GMCC
Refrigerant Type
R32
Refrigerant Charge, g
1250
Design pressure (inlet / outlet)
1.7 / 4.3
Gas Pipe Diameters, mm (inch)
2 х 9.52 (3/8)
Liquid Pipe Diameters, mm (inch)
2 х 6.35 (1/4)
Drain Pipe Diameter, mm (inch)
16,0
Electrical Inter-unit Connection, cores x mm²
5 × 1.5 (x2)
Maximum Line Length, m
40m (for 2 units) / 25m (for a single unit)
Maximum Line Height Difference, m
15m (between indoor and outdoor units) / 10m (between indoor units)
Warranty
3 years

General Information

Model
Multi-Split System (Set) ERGO ACI 1835 ODU MSH (2) + ACI 0935 IDU MSW W x 2
SKU
ACI 1835 ODU MSH(2) + ACI 0935 I
Condition
New (Original factory package)
Warranty
Official manufacturer warranty

Delivery & Payment

Nova Poshta delivery across Ukraine

Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.

Payment & Pick-up

Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.

Shopping Cart

0 items

Your cart is empty

Add items from the catalog to place an order.

Explore Catalog