PV Module Optimizer Deye SUN-XL02-A 700W 80V 15A
Deye
3,384 ₴
1 / 3SKU МРРТ-10А
Solar battery charge controller is a device for regulating the charge and discharge of a storage battery bank. It is connected between the power source (solar panel) and the energy storage (battery) to perform the following functions:
overcharge protection – when the solar panel generates excessive power and the battery is already fully charged, the controllers disconnect the power source to reduce current flowing into the battery;
deep discharge protection – when there is excessive energy consumption and the battery is discharged below allowable levels, the controller disconnects some or all of the load;
reverse current blocking – solar panels conduct current through the battery in one direction. At night, panels can leak part of this current in the reverse direction, which may cause slight battery discharge. Charge controllers prevent this by acting as a one-way valve;
overload protection – if the current flowing through the batteries significantly exceeds their rated capacity, it can cause overheating or fire hazard. Controllers prevent these overloads. In larger systems, dual protection using circuit breakers or fuses is recommended.
Charge controllers are not optional components — they are an absolute necessity that enables charging batteries from solar energy. They are an integral part of off-grid and hybrid solar power plants, ensuring safe and efficient operation.
Technical specifications
Support for all battery types (GEL, AGM, Li-ion, LiFePO4)
System nominal voltage: 12/24/48V (auto-sensing)
When using lead-acid batteries:
Maximum solar array power, W: 240/480/960 (for 12/24/48V systems respectively)
DC Input (in lead-acid battery mode):
MPPT operating range, V: 15-70
MPPT open-circuit voltage, V: 80
Maximum peak current, A: 10
DC Output (when operating with lead-acid battery):
Maximum current, A: 10
Maximum battery voltage, V: 14.2/28.4/56.6 (for 12/24/48V systems respectively)
Battery float charge voltage, V: 14.4/28.8/57.6 (for 12/24/48V systems respectively)
When using lithium-ion batteries:
Nominal battery voltage: 12.6/25.2/50.4V (auto-sensing)
Maximum solar array power: 126/252/504W (for 12.6/25.2/50.4V systems respectively)
MPPT operating range, V: 15-70
MPPT open-circuit voltage, V: 80
Maximum MPPT current, A: 10