Motion Sensor (100W, 220V)
Voltronic
231 ₴

SKU FireProtect 2 RB (Heat) B
FireProtect 2 (Heat) Jeweller is a wireless fire detector with a built-in siren. Designed for indoor installation. Detects rapid temperature rise. The detector can operate without a hub.
Available in two modifications: with non-replaceable batteries (designated SB in the name) operating for up to 10 years, and with replaceable batteries (designated RB in the name) operating for up to 7 years.
The detector operates within an Ajax system, communicating with the hub via the proprietary Jeweller secure radio protocol. Communication range with the hub without obstacles is up to 1700 meters.
The detector is equipped with a siren (piezoelectric buzzer) for audible alarms and event notifications with a sound volume of up to 85 dB (at a distance of 3 meters from the detector). The detector is always active, responding to fire 24/7 regardless of the system security mode.
FireProtect 2 is protected by a tamper switch. It monitors the removal of the detector from the SmartBracket mounting panel: the detector responds with LED indication and sends alerts to Ajax app users and the central monitoring station (CMS).
Ajax automation devices can respond to FireProtect 2 alarms and perform user-configured actions via automation scenarios. For example, a WallSwitch relay can turn on the ventilation system and emergency lighting upon alarm.
Heat sensor
Two built-in Class A1 thermistors in FireProtect 2 are responsible for detecting a rapid temperature rise and exceeding the temperature threshold. Class A1 thermistors notify of an alarm upon detecting a rapid temperature rise or static temperature within the range of +54°C to +65°C.
FireProtect 2 will report exceeding the permissible temperature threshold when its value exceeds +64°C. The detector will report a rapid temperature rise if the temperature increases by 10°C within one minute. If the temperature spikes by 20°C or more, the detector triggers an alarm immediately.
Test/Mute button
To activate the Test/Mute button, lightly press the center of the front panel by hand or using a suitable object (such as a broom handle) if the detector is installed in a hard-to-reach place. Test/Mute is a mechanical button located under the detector's front panel.
The button performs several functions:
In normal mode, it initiates a detector functionality test.
In case of an alarm, it mutes the detector alarm or the interconnected alarm of all system fire detectors for 10 minutes.
In case of a fault or low battery charge, it mutes the acoustic and LED indications for 12 hours.
Interconnected fire detector alarm
All FireProtect 2 fire detectors support the interconnected alarm function. The feature activates the built-in sirens of all fire detectors in the system as soon as at least one detector detects an alarm. FireProtect 2 sirens activate within 20 seconds of alarm detection. FireProtect and FireProtect Plus activate within the hub-detector polling interval configured in Jeweller (or Jeweller/Fibra) settings, but no later than 60 seconds.
FireProtect 2 detectors feature differentiated sound and LED indication for alarm types, making it easier for users to distinguish them. During an interconnected alarm, FireProtect 2 detectors reproduce the exact type of alarm that was triggered by the initiating detector. The initiating detector additionally indicates the alarm with an LED. FireProtect and FireProtect Plus detectors indicate all alarm types with the same sound pattern.
The Ajax system can transmit alarms and events to the PRO Desktop monitoring software, as well as to a Central Monitoring Station (CMS) in SurGard (Contact ID), SIA DC-09 (ADM-CID), ADEMCO 685, and other protocol formats.
Brand
Ajax
Model
FireProtect 2 RB (Heat)
Detector category
Heat detector
Detector type
Wireless
Sensing elements
Temperature sensor
Compatibility
Hub Plus,
Hub 2 (2G),
Hub 2 (4G),
Hub 2 Plus,
Hub Hybrid (2G),
Hub Hybrid (4G),
ReX,
ReX 2
Hazardous temperature detection
Sensing element complying with Class A1 temperature sensor requirements of EN 54-5 and BS 5446-2 standards. Temperature threshold alarm at temperatures above 64°C. Rapid temperature rise alarm when temperature increases by more than 10°C in 1 minute (or faster)
Tamper protection
Tamper switch against detachment. Alerts on attempts to tear the detector from the surface or remove it from the mounting panel.
Spoofing protection with device authentication. Connection loss detection within 15 minutes. Detection time depends on the settings for the number of undelivered data packets (configured in Jeweller or Jeweller/Fibra settings). Fixed polling period: 300 seconds.
Communication
Jeweller communication technology. Proprietary wireless technology for transmitting alarms and events. Features: - Two-way communication.
- Device spoofing prevention.
- Block encryption with floating key.
- Instant notifications.
- Remote configuration via Ajax app.
Radio frequency bands 868.0 – 868.6 MHz
Maximum effective radiated power (ERP) up to 20 mW. Automatic power control to reduce power consumption and radio interference. GFSK radio signal modulation. Radio communication range up to 1700 m between detector and hub (or radio signal range extender) in open space. Radio communication encryption: all stored and transmitted data is protected by block encryption with a floating key. Frequency hopping to prevent radio interference and jamming.
Connection method to control panel
Wireless
Wireless signal range
1700 m
Additional features
Built-in siren: volume 85 dB at a distance of 3 meters. Audible alarm alert. Active until the cause of tripping is eliminated or until muted by the user. Interconnected fire detector alarm: fire detectors in the system sound their built-in sirens as soon as at least one detector registers an alarm. Interconnected alarm activates within one hub-detector polling interval, but no later than 20 seconds. LED indication: green — power indication (LED indicator on the enclosure flashes once every 56 seconds, complying with EN 50291); yellow — malfunction indication (LED lights up upon detecting faults, e.g., low battery, smoke chamber contamination, or end of service life); red — fire alarm indication (LED lights up when the detector detects a fire alarm). Front panel button: in normal mode, pressing it runs a smoke chamber test; during alarm or malfunction, pressing it silences the detector sound alert.
Protection rating
IP20
Operating temperature range
0 °C to +50 °C
Operating humidity
Up to 80%
Power supply
2 x CR123A
Dimensions
44×86×86 mm
Weight
146 g
Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.
Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.