AGM Lead-Acid Traction Battery LP 6-DZM-9 Ah Clearance 01.20251 / 5
988 ₴
In Stock
1

AGM Lead-Acid Traction Battery LP 6-DZM-9 Ah Clearance 01.2025

SKU 42062

Description

Clearance reason - manufacturing year: 012025

AGM Lead-Acid Battery

External universal SLA battery manufactured using AGM technology - a completely sealed external power source that requires no maintenance during storage and operation.

The manufacturing technology of universal external AGM (absorbent glass mat) batteries features an absorbent fiberglass pad inside the battery. Batteries of this type cope excellently with increased loads.

A traction battery is the optimal solution if you need a reliable device to supply electrical power to equipment. The traction battery model is primarily designed to generate electricity necessary to provide uninterrupted power supply to specialized equipment: electric carts, forklifts, and others.

Advantages of the AGM Battery:

  • AGM battery charge/discharge cycle life is 400* (generally 5 years, depending on operating conditions).
  • The battery can be installed in residential areas. The absence of free liquid electrolyte between the plates and complete housing tightness eliminate acid leaks and guarantee the absence of harmful vapors.
  • In practical use, these AGM lead-acid batteries show stable results when operating in low (-20°C) and high (+50°C) ambient temperature conditions.
  • During operation, the AGM lead-acid battery is capable of withstanding prolonged discharge, cyclic discharge, deep discharge, and high-current discharge.
  • Batteries of this type feature low self-discharge rates during long-term storage and reliable self-protection against over-discharge and overcharging.

Features of AGM Battery Production

Inside the storage battery manufactured using AGM technology, porous insulating pads of fine fiberglass are placed. The separators and electrode plates are pressed tightly against each other. Thus, no free liquid electrolyte remains between the battery plates, as it is contained within the separator and the active part of the electrodes.

The amount of liquid electrolyte is dosed so that small pores are filled with acid, while large ones ensure gas circulation.

The battery design features an improved gas recombination system - oxygen and hydrogen generated as a result of chemical processes do not manage to evaporate beyond the sealed housing before condensation occurs.

How does a DZM battery differ from a standard lead-acid SLA battery?

DZM batteries are designed to operate with a higher starting current than AGM batteries, making them an ideally correct solution for boats, electric bikes, and other electric traction transport.

Application Areas: What is an AGM Lead-Acid Battery Used For?

The universal external charging battery is used:

  • In emergency notification systems.
  • In boats.
  • In bicycles and other electric traction transport.
  • In telecommunications and other communication systems, including as an external SLA battery for charging mobile phones, walkie-talkies, etc.
  • For video surveillance, security, intruder, fire, and other alarm system equipment.
  • In server station uninterruptible power supply systems.
  • As a power source for medical, laboratory, commercial, and other specialized equipment.
  • In alternative energy storage systems (solar panel batteries).
  • As a battery for emergency or LED lighting fixtures.
  • As batteries for uninterruptible power supply units and UPS.

Which SLAs are suitable for emergency lighting systems in Ukraine, and which SLA should be bought for a UPS?

Battery selection depends on the power rating of the consumers to be connected, as well as the required backup operating time of the electrical equipment from the SLA.

The external AGM battery for a UPS must have sufficient capacity reserve, a wide operating temperature range, and a long service life.

Before deciding which battery is best to buy for a UPS, carefully study the parameters of the uninterruptible power source and determine the amount of time required for autonomous operation of the electrical equipment.

AGM batteries are in high demand among consumers who want to buy an inexpensive and universal SLA for a heating boiler, emergency lighting systems, or autonomous water supply.

Before choosing a battery for solar panels, uninterruptible power supplies, or other purposes, consult a specialist.

How to Avoid Storage Battery Capacity Loss During Frequent Power Outages?

Two important maintenance rules for AGM, GEL, MG batteries:

  1. You should not frequently discharge the SLA by more than 30% of its capacity (take this into account when calculating battery capacity)
  2. After discharge, the battery must be fully charged with a current of 1/10 of its capacity for 10 hours

IMPORTANT! If a group of multiple batteries connected in parallel or series is used, then:

  • all batteries must have identical capacity,
  • be of the same type (AGM, GEL, or MG),
  • have identical voltage, an identical number of charge/discharge cycles,
  • be from the same batch of the same trademark.

Violation of these requirements leads to the premature failure of one or more SLAs and is not a warranty case. You can get more detailed information from our article.

On the official LogicPower website, you can order storage batteries for UPS and other battery types with delivery across Ukraine. Price is directly from the manufacturer.

Warranty - 6 months.

The company ensures 100% fulfillment of warranty obligations. Maintenance and repair of LogicPower equipment is carried out in certified service centers.

*Depending on operating conditions

Specifications

Technical Specifications

Nominal capacity, Ah
9
Nominal voltage, V
12
Type
AGM lead-acid
Internal resistance, mOm
22
Charging voltage (buffer mode), V
13,5-13,8
Charging voltage (cyclic mode), V
14,5-14,9
Peak discharge current (100 ms), A
100
Short-circuit current, A
405
Terminal type
T2
Number of cycles
400
Housing material
plastic
Battery storage temperature, °C
-20 ~ +50
Operating charge temperature, °C
-10 ~ +50
Operating discharge temperature, °C
-15 ~ +50
Length, mm
151
Width, mm
65
Height, mm
112
Height with terminals, mm
118
Warranty, months
6
Weight, kg
2.56

General Information

Model
AGM Lead-Acid Traction Battery LP 6-DZM-9 Ah Clearance 01.2025
SKU
42062
Condition
New (Original factory package)
Warranty
Official manufacturer warranty

Delivery & Payment

Nova Poshta delivery across Ukraine

Dispatch to post branches, parcel lockers, or by courier to your doorstep. All packages are insured for 100% of value. Delivery time: 1–3 business days.

Payment & Pick-up

Flexible options: Cash on delivery at Nova Poshta branch or bank transfer invoice (IBAN) for individuals, FOP and companies.

Shopping Cart

0 items

Your cart is empty

Add items from the catalog to place an order.

Explore Catalog